FortiGuard Labs is aware a path-traversal vulnerability (CVE-2022-0902) that affects ABB Totalflow flow computers and remote controllers widely used by oil and gas utility companies. Successfully exploiting the vulnerability allows an attacker to inject and execute arbitrary code. The vulnerability is a path-traversal vulnerability in ABB Totalflow flow computers and remote controllers.Why is this Significant?This is significant because the new vulnerability (CVE-2022-0902) affects ABB TotalFlow flow computers and remote controllers widely used by oil and gas utility companies. ABB TotalFlow is used to calculate oil and gas volume and flow rates and is also used for billing and other purposes.By successfully exploiting the vulnerability, an attacker may be able to hinder affected oil and gas companies’ abilities to correctly measure oil and gas flow, which may lead to safety issues and interruption of business.What is CVE-2022-0902?CVE-2022-0902 is a path-traversal vulnerability (CVE-2022-0902) in ABB TotalFlow flow computers and remote controllers. The vulnerability allows an attacker to gain access to restricted directories in ABB flow computers leading to arbitrary code execution in an affected system node.CVE-2022-0902 has a CVSS score of 8.1.What Products are Affected by the Vulnerability?According to the advisory issued by ABB, the following products are affected by the vulnerability:• RMC-100• RMC100L ITE• XIO• XFCG5• XRCG5• uFLOG5• UDCAll versions of the products without the latest update are vulnerable to CVE-2022-0902.Is CVE-2022-0902 being Exploited in the Wild?FortiGuard Labs is not aware that CVE-2022-0902 is exploited in the wild.Has the Vendor Released an Advisory?Yes. Please see the Appendix for a link to “ABB Flow Computer and Remote Controllers Path Traversal Vulnerability in Totalflow TCP protocol can lead to root access CVE ID: CVE-2022-0902”.Has the Vendor Released a Patch?Yes, the vendor released a firmware update.What is the Status of Protection?FortiGuard Labs is currently investigating protection for CVE-2022-0902. We will update this Threat Signal when protection becomes available.Any Suggested Mitigation?The advisory issued by ABB includes mitigation and workarounds information. See the Appendix for a link to “ABB Flow Computer and Remote Controllers Path Traversal Vulnerability in Totalflow TCP protocol can lead to root access CVE ID: CVE-2022-0902”.
More Stories
openjpeg2-2.5.3-1.fc40
FEDORA-2024-272544ceb9 Packages in this update: openjpeg2-2.5.3-1.fc40 Update description: Update to openjpeg-2.5.3 Fix 2 heap-buffer-overflow Read More
libxml2-2.12.9-1.fc40
FEDORA-2024-9f3765a04b Packages in this update: libxml2-2.12.9-1.fc40 Update description: Update to 2.12.9 Fixes CVE-2024-40896 Read More
libxml2-2.12.9-1.fc41
FEDORA-2024-867a14de12 Packages in this update: libxml2-2.12.9-1.fc41 Update description: Update to 2.12.9 Fixes CVE-2024-40896. Read More
iwd-3.3-1.fc40 libell-0.71-1.fc40
FEDORA-2024-0fa283c43a Packages in this update: iwd-3.3-1.fc40 libell-0.71-1.fc40 Update description: iwd 3.3: Fix issue with handling External Authentication. iwd 3.2: Fix...
iwd-3.3-1.fc41 libell-0.71-1.fc41
FEDORA-2024-256818da09 Packages in this update: iwd-3.3-1.fc41 libell-0.71-1.fc41 Update description: iwd 3.3: Fix issue with handling External Authentication. iwd 3.2: Fix...
A Vulnerability in Apache Struts2 Could Allow for Remote Code Execution
A vulnerability has been discovered in Apache Struts2, which could allow for remote code execution. Apache Struts2 is an open-source...