FEDORA-EPEL-2024-7ac44bd3cc
Packages in this update:
python-aiohttp-3.9.5-2.el9
Update description:
Security fix for CVE-2024-52304
python-aiohttp-3.9.5-2.el9
Security fix for CVE-2024-52304
python-aiohttp-3.9.5-2.fc39
Security fix for CVE-2024-52304
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Hugging Face Transformers. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 8.8. The following CVEs are assigned: CVE-2024-11394.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Hugging Face Transformers. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 8.8. The following CVEs are assigned: CVE-2024-11393.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Hugging Face Transformers. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.5. The following CVEs are assigned: CVE-2024-11392.
This vulnerability allows local attackers to escalate privileges on affected installations of McAfee Total Protection. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The ZDI has assigned a CVSS rating of 6.7. The following CVEs are assigned: CVE-2024-49592.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Trend Micro Deep Security Agent. Authentication is required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 7.5. The following CVEs are assigned: CVE-2024-51503.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2024-52573.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2024-52571.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2024-52567.