This vulnerability allows remote attackers to execute arbitrary code on affected installations of SolarWinds Orion Platform. Authentication is required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 8.8. The following CVEs are assigned: CVE-2023-50395.
Category Archives: Advisories
ZDI-24-170: SolarWinds Orion Platform AppendCreatePrimary SQL Injection Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on affected installations of SolarWinds Orion Platform. Authentication is required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 8.8. The following CVEs are assigned: CVE-2023-35188.
ZDI-24-182: ESET Smart Security Premium ekrn Link Following Local Privilege Escalation Vulnerability
This vulnerability allows local attackers to escalate privileges on affected installations of ESET Smart Security Premium. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2024-0353.
ZDI-24-181: Siemens Simcenter Femap MODEL File Parsing Uninitialized Pointer Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Simcenter Femap. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2024-24925.
ZDI-24-180: Siemens Simcenter Femap MODEL File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Simcenter Femap. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2024-24924.
ZDI-24-179: Siemens Simcenter Femap MODEL File Parsing Out-Of-Bounds Read Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Simcenter Femap. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2024-24923.
ZDI-24-178: Siemens Simcenter Femap MODEL File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Simcenter Femap. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2024-24922.
ZDI-24-177: Siemens Simcenter Femap MODEL File Parsing Memory Corruption Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Simcenter Femap. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2024-24921.
ZDI-24-176: Siemens Simcenter Femap MODEL File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Simcenter Femap. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2024-24920.
ZDI-24-175: Siemens Tecnomatix Plant Simulation WRL File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The ZDI has assigned a CVSS rating of 7.8. The following CVEs are assigned: CVE-2024-23798.