Description
The accidental addition of a data-structure sentinel can cause serious programming logic problems.
Data-structure sentinels are often used to mark the structure of data. A common example of this is the null character at the end of strings or a special sentinel to mark the end of a linked list. It is dangerous to allow this type of control data to be easily accessible. Therefore, it is important to protect from the addition or modification of sentinels.
Modes of Introduction:
– Architecture and Design
Likelihood of Exploit: High
Related Weaknesses
Consequences
Integrity: Modify Application Data
Generally this error will cause the data structure to not work properly by truncating the data.
Potential Mitigations
Phase: Implementation, Architecture and Design
Description:
Encapsulate the user from interacting with data sentinels. Validate user input to verify that sentinels are not present.
Phase: Implementation
Description:
Proper error checking can reduce the risk of inadvertently introducing sentinel values into data. For example, if a parsing function fails or encounters an error, it might return a value that is the same as the sentinel.
Phase: Architecture and Design
Description:
Use an abstraction library to abstract away risky APIs. This is not a complete solution.
Phase: Operation
Description:
Use OS-level preventative functionality. This is not a complete solution.
CVE References
More Stories
The Most Dangerous Vulnerabilities in Apache Tomcat and How to Protect Against Them
Apache Tomcat is an open-source web server and servlet container that is widely used in enterprise environments to run Java...
ZDI-CAN-18333: A Critical Zero-Day Vulnerability in Microsoft Windows
Zero-day vulnerabilities are a serious threat to cybersecurity, as they can be exploited by malicious actors to gain unauthorized access...
CWE-669 – Incorrect Resource Transfer Between Spheres
Description The product does not properly transfer a resource/behavior to another sphere, or improperly imports a resource/behavior from another sphere,...
CWE-67 – Improper Handling of Windows Device Names
Description The software constructs pathnames from user input, but it does not handle or incorrectly handles a pathname containing a...
CWE-670 – Always-Incorrect Control Flow Implementation
Description The code contains a control flow path that does not reflect the algorithm that the path is intended to...
CWE-671 – Lack of Administrator Control over Security
Description The product uses security features in a way that prevents the product's administrator from tailoring security settings to reflect...